Spacer
Spacer HKM - Technical data  - Ihr Partner für Kraftmessung, Wägetechnik und Sensorik Spacer
Spacer
Spacer
Spacer Spacer
Spacer
Spacer
Force measurement
Weighing technology
Sensor technology
Spacer
Spacer
Spacer Spacer Spacer Spacer Spacer Spacer
Spacer
Spacer
Spacer
HKM - Technical data  - Ihr Partner für Kraftmessung, Wägetechnik und Sensorik

Spacer

Technical data

Shear force transducer SK

Type

Nominal load

Accuracy

Material

Dimensions

L*B*H (mm)

SK 1.0

2 kN

0.25 % f.s.

Aluminium

130*30*30

SK 1.1

5 kN

0.25 % f.s.

Aluminium

SK 1.2

10 kN

0.25 % f.s.

Steel

SK 1.3

20 kN

0.25 % f.s.

Steel

SK 2.0

50 kN

0.25 % f.s.

Steel

170*48*48

SK 2.1

100 kN

0.25 % f.s.

f.s.: full scale, i.e. accuracy figure with reference to the nominal load

The following variants of output signals are available:
            ca. 2mV/V      without measuring amplifier
            4-20mA          with integrated measuring amplifier
            (other levels on request)

Nominal temperature range -10°C to +50°C





Dual shear force transducer DK

Type

Nominal load

Accuracy

Material

Dimensions

L*B*H (mm)

DK 1.0

15 kN

0.25 % f.s.

Aluminium

300*30*30

DK 2.0

20 kN

0.25 % f.s.

Aluminium

420*35*35

DK 3.0

100 kN

0.25 % f.s.

Steel

270*48*48

f.s.: full scale, i.e. accuracy figure with reference to the nominal load

The following variants of output signals are available:
            ca. 2mV/V      without measuring amplifier
            4-20mA          with integrated measuring amplifier
            (other levels on request)

Nominal temperature range -10°C to +50°C





Shear force load cell SW

Type

Nominal load

Accuracy

Dimensions

L*B*H in mm

Material

SW 1.01100 N0.5 % f.s.

40*20*40

Aluminium
SW 1.02200 N0.5 % f.s.Aluminium

SW 1.0

500 N

0.25 % f.s.

Aluminium

SW 1.1

1 kN

0.25 % f.s.

Aluminium

SW 1.2

2 kN

0.25 % f.s.

Aluminium

SW 1.3

3 kN

0.25 % f.s.

Steel

SW 1.4

5 kN

0.25 % f.s.

Steel

SW 2.0 *

5 kN

0.25 % f.s.

80*25*90

Aluminium

SW 2.1 *

10 kN

0.25 % f.s.

SW 3.0

10 kN

0.25 % f.s.

80*25*80

Steel

SW 3.1

20 kN

0.25 % f.s.

SW 4.0 *

50 kN

0.25 % f.s.

68*38*78

Steel

SW 5.0 *50 kN0.25 % f.s.

108*54*108

Steel
SW 5.1 *80 kN0.25 % f.s.
SW 6.0 *100 kN0.25 % f.s.

120*80*120

Steel

f.s.: full scale, i.e. accuracy figure with reference to the nominal load

The following variants of output signals are available:
            ca. 2mV/V      without measuring amplifier
            4-20mA          with integrated*/external measuring amplifier
            (other levels on request)

Nominal temperature range -10°C to +50°C





Pressure measuring cell DD

Type

Nominal load

Accuracy

Output signals

(without mea-suring amplifier)

Dimensions in mm

Diameter             Height

Material

DD 1.0

50 kg

0.5 % f.s.

ca. 1.8 mV/V

20

9

Aluminium

DD 1.1

100 kg

Stainless steel

DD 2.0 *

500 kg

0.25 % f.s.

ca. 2 mV/V

94

48

Steel, nickel plated

DD 2.1 *

1000 kg

DD 2.2 *

2000 kg

DD 2.3 *

4000 kg

DD 2.4 *

6000 kg

DD 3.0 *

10 t

0.25% f.s.ca. 2 mV/V

114

60

Steel, nickel plated

DD 3.1 *

20 t

DD 4.0

5000 kg

0.25 % f.s.

1 mV/V

99

51.5

Steel

f.s.: full scale, i.e. accuracy figure with reference to the nominal load

The following variants of output signals are also available:          
            4-20mA          with integrated*/external measuring amplifier
            (other levels on request)

Nominal temperature range -10°C to +50°C




Platform load cell BR

Type

Nominal load

Accuracy

Dimensions

L*W*D in mm

Material

BR 1.0

5 kg

0.25 % f.s.

80*14*14

Alum.

BR 2.0

10 kg

0.25 % f.s.

130*30*22

Alum.

BR 2.1

35 kg

0.25 % f.s.

BR 2.2100 kg0.25 % f.s.

f.s.: full scale, i.e. accuracy figure with reference to the nominal load

The following output signal is available:
            app. 2mV/V     without measuring amplifier
            (other levels with external measuring amplifier on request)

Nominal temperature range -10°C to +50°C





Tension force transducer ZU

Type

Nominal load

Accuracy

Dimensions without spherical rod ends

Diameter
/mm
   Length
   /mm
   Thread

Dimensions with spherical rod ends
(optionally)

Typehole center
distance/mm

ZU 1.0

5 kN

0,5 % f.s.

22

70

M12

EF 12

132 - 140

ZU 2.0

10 kN

0,5 % f.s.

28

105

M12

EF 12

170 - 180

ZU 3.0

20 kN

0,5 % f.s.

35

105

M14

EF 15

185 - 195


f.s.: full scale, i.e. accuracy figure with reference to the nominal load

The following variants of output signals are available:
            app. 1,5mV/V     without measuring amplifier
            4-20mA             with external measuring amplifier
            (other levels on request)

Nominal temperature range -10°C to +50°C

 

 
 
Pressure transducer DA

Type

Nominal pressure

Accuracy

Mechanical data

Connection      Size in mm

Material

DA 1.0

10 bar

0.5 % f.s.

G 1/2

d42 x 100

Alum.

DA 1.1

20 bar

0.5 % f.s.

G 1/2

Alum.

DA 2.0

200 bar

0.5 % f.s.

G 1/2

Stainless steel

f.s.: full scale, i.e. accuracy figure with reference to the nominal load

The following variants of output signals are available:
            1- 9 mA          with integrated measuring amplifier
            4-20 mA         with integrated measuring amplifier
            (other levels on request)

Nominal temperature range -10°C to +50°C

 
Spacer

Balken
Spacer
Spacer
HKM-Messtechnik GmbH
Germany
Ziegelhofstr. 228
D-79110 Freiburg
Phone +49(0)761 / 896070
Fax     +49(0)761 / 8960766
  e-mail     Imprint     print